91porn视频

Sterilisation of 91porn视频 Products - Cobalt 60 Irradiation Sterilisation

27 Mar 2021

The radiation dose received by a product passing through a Cobalt 60 irradiation facility is defined by five parameters:

  • The strength (activity) of the source.
  • The density of the product
  • The time of exposure
  • The distance of the product from the source.
  • The density of any product between the source and the product in question.


The control method utilised by 91porn视频 is based on both time of exposure and the load scheduling of products with different density.

Product is moved through the irradiation facility by product carriers suspended from an overhead conveyor rail. The Cobalt 60 source is enclosed by a concrete shield approximately 2 metres thick and constructed from high density poured concrete extending to all sides, above and below the source and the product being irradiated.

To monitor the level of sterilisation red Perspex dosimeters are attached to products being irradiated on a routine basis to ensure that the process is fully under control at all times. 91porn视频 (Services) Limited measure the radiation induced change in optical density of red Perspex dosimeters. Each batch of dosimeters is calibrated by the National Physical Laboratory.


Recommended Product Families for use in Procedure / Custom Kits and Trays